The Watts Up? Pro has internal memory to handle over 2,000 records of data. It also comes with software and a USB interface. The software automatically graphs all the data and includes a Payback Calculator so you can tell how long it will take for a new energy efficient appliance to pay for itself.
As a data logger, the Pro model records all the data into non-volatile (stored even if power is lost) memory. Over one thousand data points can be stored, starting with a sampling rate resolution of one second. The sample rate is user selectable or can be automatically set (resolution decreases over time) so ears of usage can be accurately recorded. The included USB connection and software allows quick download of data to a PC. Data and graphs can also be exported to popular spreadsheet and word processing programs for further analysis.
Display Values:
Minimum wattage
Maximum wattage
Cost, in dollars and cents
Average monthly cost
Average monthly kwh
Time
Power factor
Apparent Power
True power
Cumulative power (kwh)
Minimum RMS voltage
RMS voltage
Maximum RMS voltage
Minimum RMS current
RMS current
Maximum RMS current
Minimum wattage
Maximum wattage
Duty cycle
Power cycle (PRO)
Frequency (Hz)
Technical Specs:
120 VAC, 60 Hz, 15 amps
True RMS power measured and displayed
+/- 1.5%, +/- 3 counts of the displayed value
Below 60 watts, amps and power factor lose accuracy.
Higher ratings of 100-277v, 50/60Hz, and 20 amps require appropriate country specific cord set and receptacle, and is not UL listed. Internal electronics are the same.
Pro and Pro ES Models include a USB interface.
Main supply voltage fluctuations not to exceed +/- 10% of the nominal voltage
Rate can be entered from $0.001 to $85.00 per kilowatt hour, in tenths of a penny
Input via 6' electric cord, output via outlet on top of meter
Indoor use only
Weight: 1.5 lbs (0.7 kg)
Dimensions: 7" x 4" x 2" (18cm x 10cm x 5cm)
For UL rating:
Wattsup? is UL listed to standard UL 610010-1, and CAN CAS/C22.2 61010-1 (domestic version only)
Altitude up to 2000 meters
Temperature 5 C to 40 C
Maximum relative humidity 80% for temperatures up to 31 C decreasing linearly to 50% relative humidity at 40 C