The Watts Up? Pro ES comes with all the features of the Pro model, but boasts over 13,000 records of memory for sophisticated data collection. Over a week's worth of data can be collected with a resolution between records of only one minute. The sample interval (time between records) is user selectable between one second and one day.

 

$189.95 (plus taxes and shipping)

 
View product data sheet (Adobe PDF)

Display Values:

  • Minimum wattage
  • Maximum wattage
  • Cost, in dollars and cents
  • Average monthly cost
  • Average monthly kwh
  • Time
  • Power factor
  • Apparent Power
  • True power
  • Cumulative power (kwh)
  • Minimum RMS voltage
  • RMS voltage
  • Maximum RMS voltage
  • Minimum RMS current
  • RMS current
  • Maximum RMS current
  • Minimum wattage
  • Maximum wattage
  • Duty cycle
  • Power cycle (PRO)
  • Frequency (Hz)

Technical Specs:

  • 120 VAC, 60 Hz, 15 amps
  • True RMS power measured and displayed
  • +/- 1.5%, +/- 3 counts of the displayed value
  • Below 60 watts, amps and power factor lose accuracy.
  • Higher ratings of 100-277v, 50/60Hz, and 20 amps require appropriate country specific cord set and receptacle, and is not UL listed. Internal electronics are the same.
  • Pro and Pro ES Models include a USB interface.
  • Mains supply voltage fluctuations not to exceed +/- 10% of the nominal voltage
  • Rate can be entered from $0.001 to $85.00 per kilowatt hour, in tenths of a penny
  • Input via 6' electric cord, output via outlet on top of meter
  • Indoor use only
  • Weight: 1.5 lbs (0.7 kg)
  • Dimensions: 7" x 4" x 2" (18cm x 10cm x 5cm)

For UL rating:

  • Wattsup? is UL listed to standard UL 610010-1, and CAN CAS/C22.2 61010-1 (domestic version only)
  • Altitude up to 2000 meters
  • Temperature 5 C to 40 C
  • Maximum relative humidity 80% for temperatures up to 31 C decreasing linearly to 50% relative humidity at 40 C
  • Installation Category II